FCI Tech

Home
Catalog
Computers & Mobile Devices
Power Accessories
UPS & Accessories
VERTIV Liebert PSI5 Lithium-Ion 3000VA Short Depth 3U Rack/Tower UPS 120V

VERTIV Liebert PSI5 Lithium-Ion 3000VA Short Depth 3U Rack/Tower UPS 120V

In Stock
SKU #
LIP5300SR120
Mfr #
PSI5-3000SRT120LI
Manufacturer
VERTIV Liebert
Description
Designed for server rooms, network closets, and other distributed IT applications, this PSI5 Lithium-Ion 3000VA Short Depth 3U Rack/Tower UPS 120V from Liebert offers solid power capacity in a small rack/tower convertible form factor. This UPS has an output of 3000 VA/2700W and an input of 120 VAC at 60 Hz, allowing for the non-programmable NEMA L5-30R outlet, six non-programmable NEMA 5-15R/20R outlets, and 3 programmable NEMA 5-15/20R outlets to adequately distribute backup power.Liebert has designed this UPS to feature pure sinewave output, USB ports, emergency power off, hot swappable lithium-ion batteries, and a rotatable LCD display panel. The PSI5 sports a recharge time of two hours to 90% and has a runtime of 7.7 minutes at full-load and 18.3 minutes at half-load. Along with visual warnings on the LCD display, the PSI5 can also output audible-tone indicators that inform you of faults in the system, low battery, battery mode, and overloads. Automatic Voltage Regulation (AVR) also comes standard with this UPS as a mode. Moreover, a NEMA L5-30P plug is the primary input connection of this UPS, and with a 10' cord, you can easily install this convertible design in a way that's appropriate for your setup.LCD Display Panel Provides information about the utility and UPS conditions:Power On/OffPower ModeAVR On/OffBattery ModeEstimated Backup TimeWarnings and Fault CodesUPS Operation ParametersAlarms On/OffOverload InformationProgrammable Outlet InformationBenefits of Liebert PSI5 Lithium-Ion Key Benefits The Liebert PSI5 Lithium-Ion line-interactive UPSs are ideally suited to protect critical infrastructure in edge or distributed IT applications. The life expectancy of lithium-ion batteries is up to 3x that of VRLA batteries, up to 10 years, delivering 50% or more in TCO savings versus VRLA batteries. This is chiefly because the Liebert PSI5 Lithium-Ion requires fewer battery replacements over its lifespan. You save not only on the cost of batteries but on the labor required to replace them.USB Connection Basic monitoring of the PSI5 and unattended controlled shutdown of your computer in case of a power failure can be done using the Liebert Power Assist software via the USB port.Programmable Outlets The PSI5 features programmable outlets that can be tweaked to run for a certain amount of time.Modes of Operation Off Mode: The UPS input is plugged into a stable, nominal source, but the outlets are turned off. The internal batteries are charging.On/Normal Mode: The UPS input is plugged into a stable, nominal source, and the outlets are turned on. The internal batteries are charging.On/Automatic Voltage Regulation (AVR)/Boost Mode: The UPS input is plugged in, but the voltage source is abnormally low (brown-out). The UPS automatically corrects the low voltage and allows the outlets to be on with the normal, expected voltage. The internal batteries are charging.On/Automatic Voltage Regulation (AVR)/Buck Mode: The UPS input is plugged in, but the voltage source is abnormally high. The UPS automatically corrects the high voltage and allows the outlets to be on with the normal, expected voltage. The internal batteries are charging.On/Battery Mode: The UPS input is not plugged in or the voltage source has become extremely low or high and unusable. The UPS automatically switches to the internal battery to provide normal, usable voltage to the outlets.Fault Mode: An error or fault condition has occurred. The outlets are shut off.Battery Self-Test Mode: The UPS enters a cycle of approximately 10 seconds during which it tests the internal battery. The outlets are still temporarily powered by the internal battery. Self-test mode occurs at the following instances:At startup when turning the UPS on.Automatically every 8 weeks as a self-check.Manually by pressing and holding the ON/Mute button for 3 seconds when the unit is on.

Product Information

Availability:
In Stock

Bulk Order